This is our driving KOP bot, still working on the rest of it!
09-02-2014 22:48
Dkt01It looks like you may have exposed lugs on the battery and the circuit breaker, which could enable accidents. Try covering exposed metal with heat shrink tubing or electrical tape to make everything safer.
10-02-2014 09:53
Canon reevesOk, we will get after that this afternoon, thank you for the advice!
10-02-2014 10:50
Canon reevesDo yall think we should cover the main breaker's off switch?
10-02-2014 10:52
JohnSchneider|
Do yall think we should cover the main breaker's off switch?
|
10-02-2014 11:26
Canon reevesOk, that is why we put it up there, we were just kind of afraid of it getting hit and turned off but it can't be by the ball.
10-02-2014 12:50
Whippet
|
Ok, that is why we put it up there, we were just kind of afraid of it getting hit and turned off but it can't be by the ball.
|