11-02-2016 09:41

pmangels17


Unread Re: pic: 0399 Teaser

Does this thing do two drive speeds and PTO with one shifter? This is beatuiful, and I can't wait to see the final robot.



11-02-2016 10:29

Breakaway3937


Unread Re: pic: 0399 Teaser

I know this is a teaser, so you probably won't give out much info, but is that a three stage shifter? I see three ports on the low profile pneumatic cylinder and four gears on the shifter shaft. I am very intrigued by this design and would love any information you are willing to share!



11-02-2016 11:24

asid61


Unread Re: pic: 0399 Teaser

If you are using a 3-stage cylinder, apparently it has very little force it has in the middle position (<10% of full out/full back force).



11-02-2016 12:15

mwmac


Unread Re: pic: 0399 Teaser

I think the 3 position cylinder is for selecting hi-low speeds with pto in the middle/neutral position....



11-02-2016 15:25

waialua359


Unread Re: pic: 0399 Teaser

Quote:
Originally Posted by mwmac View Post
I think the 3 position cylinder is for selecting hi-low speeds with pto in the middle/neutral position....
Yes, 3 stages, 1 for PTO.
Madison on FB pointed to a multi-position Bimba Pneumatic cylinder and that appears to be it. I bought a few for future use but mines havent come in yet. They are very pricey.
You can see the 3 input fittings also for the 3 air lines.



11-02-2016 15:51

asid61


Unread Re: pic: 0399 Teaser

Quote:
Originally Posted by mwmac View Post
I think the 3 position cylinder is for selecting hi-low speeds with pto in the middle/neutral position....
That makes sense, but the PTO has a lot of force on it and if it slipped the results would be catastrophic (presumably). Have teams used these in the past for PTOs?



11-02-2016 17:39

Aren Siekmeier


Unread Re: pic: 0399 Teaser

Quote:
Originally Posted by asid61 View Post
That makes sense, but the PTO has a lot of force on it and if it slipped the results would be catastrophic (presumably). Have teams used these in the past for PTOs?
As far as I know, only to put the drive in neutral, with a separate shift shaft engaging or disengaging (or even locking) the PTO.



02-03-2016 15:13

GautamC


Unread Re: pic: 0399 Teaser

That is a neat gearbox.
Can you show us a picture/diagram of how you plumb/connect the actuator to a solenoid?
I have always wondered how to connect these actuators when most of the solenoids we use have 2 supply ports (A&B). I haven't been able to find 3 port.
Thanks and good luck.



02-03-2016 20:14

Anonymous_Sheep


Unread Re: pic: 0399 Teaser

We utilize 2 solenoids per gear box, one for high/power take off and one for low gear. If you need more info feel free to ask.



03-03-2016 11:29

GautamC


Unread Re: pic: 0399 Teaser

I guess I'm still not sure how that would work.
You now have A1&B1 and A2&B2 giving you a total of 4 ports from the solenoid but with only 3 ports on the actuator.
If you can explain how that works that would be great.

So how do you reconcile the extra port?
A1------Actuator port 1
B1------Actuator port 2

A2------Actuator port 3
B2------??

Thanks again.



03-03-2016 12:50

Aren Siekmeier


Unread Re: pic: 0399 Teaser

Quote:
Originally Posted by GautamC View Post
I guess I'm still not sure how that would work.
You now have A1&B1 and A2&B2 giving you a total of 4 ports from the solenoid but with only 3 ports on the actuator.
If you can explain how that works that would be great.

So how do you reconcile the extra port?
A1------Actuator port 1
B1------Actuator port 2

A2------Actuator port 3
B2------??

Thanks again.
This catalog page shows which ports should be pressurised and which should be vented for the different cylinder positions. We've found that it finds the intermediate position (Position 1 on those figures) a little better when ports 1 and 3 are both pressurised (since otherwise the second rod can float). Using this, we made a table of desired cylinder position and the desired port states for each (1 for pressurized, 0 for vented). Visual inspection of this shows how to plumb the solenoid valve to achieve this (and whether you need a single or a double, which way is the default position, etc.). If there is a valve port that is not used, it should be plugged to prevent venting the entire system when the valve is actuated.



view entire thread

Reply
previous
next

Tags

loading ...



All times are GMT -5. The time now is 00:37.

The Chief Delphi Forums are sponsored by Innovation First International, Inc.


Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2017, Jelsoft Enterprises Ltd.
Copyright © Chief Delphi