everything



Finally some wire management

MaGiC_PiKaChU

By: MaGiC_PiKaChU
New: 02-06-2018 11:22 AM
Updated: 02-06-2018 11:22 AM
Views: 2528 times


Finally some wire management

Recent Viewers

  • Guest

Discussion

view entire thread

Reply

02-06-2018 01:13 PM

Classified*


Unread Re: pic: Finally some wire management

Looking great!!

...14 motor controllers?!?



02-06-2018 01:14 PM

MikLast


Unread Re: pic: Finally some wire management

Already looking forward for 3360's reveal. Cant wait to see what you guys have created.



02-06-2018 01:19 PM

AlexD


Unread Re: pic: Finally some wire management

Great work as always! This is why you are our favorite team from Sherbrooke ! Can't wait to see your creation at Montreal.



02-06-2018 01:29 PM

MaGiC_PiKaChU


Unread Re: pic: Finally some wire management

Quote:
Originally Posted by Classified* View Post
Looking great!!

...14 motor controllers?!?
that's what you get when you disregard pneumatics



02-06-2018 02:34 PM

GeeTwo


Unread Re: pic: Finally some wire management

I didn't realize those things could be used wirelessly!

Seriously, great cabling!

Quote:
Originally Posted by MaGiC_PiKaChU View Post
wireless electricity is the new thing
It got started over 150 years ago, and Tesla was building a plant over 100 years ago...



02-06-2018 02:35 PM

MaGiC_PiKaChU


Unread Re: pic: Finally some wire management

Quote:
Originally Posted by GeeTwo View Post
I didn't realize those things could be used wirelessly!

Seriously, great cabling!
wireless electricity is the new thing



02-06-2018 04:15 PM

D_Price


Unread Re: pic: Finally some wire management

Love the order. Makes my OCD sooo happy! Can't wait for the reveal.



02-07-2018 09:02 AM

DBelsh


Unread Re: pic: Finally some wire management

Beautiful cable management. Keep up the good work.



02-07-2018 02:26 PM

Volpidash2770


Unread Re: pic: Finally some wire management

What is the name of the white wire protector/organizer around the motor wires?



02-07-2018 02:36 PM

MaGiC_PiKaChU


Unread Re: pic: Finally some wire management

Quote:
Originally Posted by Volpidash2770 View Post
What is the name of the white wire protector/organizer around the motor wires?
good question. I feel like we had these in our shop since forever



02-07-2018 02:41 PM

josesantos


Unread Re: pic: Finally some wire management

Quote:
Originally Posted by MaGiC_PiKaChU View Post
good question. I feel like we had these in our shop since forever
McMaster has them listed as "spiral bundling wrap."



02-07-2018 06:28 PM

MrT8


Unread Re: pic: Finally some wire management

Very nice wiring layout. 2386 did something similar but the board is horizontal rather than vertical and “only” ten SRX’s. I’ll try to grab some pics of it tomorrow night.



02-07-2018 06:58 PM

abigailthefox


Unread Re: pic: Finally some wire management

I don't want to rain on anyone's parade, but last year we wired our electronics board very similar to this and a judge dinged us for it. We only had 10 Talons (never thought I would be saying ONLY 10 Talons but here we are...), but the judge alerted us to the fact that wiring that many high-current wires close together can cause the creation of an electromagnetic field when powered on that can interfere with other wires nearby. In fact, we had issues previously with small "blips"—unexplained robot movement, but since these "blips" were always extremely brief, rare and seemingly idiopathic, we didn't worry about them too much. I was taking physics at the time, and his explanation (the details of which escape me now) did line up with what I had just learned. Needless to say, we will be spacing out our Talons this year.

I'm not saying it's necessary to change it and it does look great, But if you get a judge who wires things professionally, you may get a comment.



02-07-2018 07:10 PM

Daniel_LaFleur


Unread Re: pic: Finally some wire management

Quote:
Originally Posted by abigailthefox View Post
I don't want to rain on anyone's parade, but last year we wired our electronics board very similar to this and a judge dinged us for it. We only had 10 Talons (never thought I would be saying ONLY 10 Talons but here we are...), but the judge alerted us to the fact that wiring that many high-current wires close together can cause the creation of an electromagnetic field when powered on that can interfere with other wires nearby. In fact, we had issues previously with small "blips"—unexplained robot movement, but since these "blips" were always extremely brief, rare and seemingly idiopathic, we didn't worry about them too much. I was taking physics at the time, and his explanation (the details of which escape me now) did line up with what I had just learned. Needless to say, we will be spacing out our Talons this year.

I'm not saying it's necessary to change it and it does look great, But if you get a judge who wires things professionally, you may get a comment.
Running high current DC near untwisted signal wires can induce spurious interference in the signal line, which is why Bell Labs researched twisted pair lines.

The signal line acts as a long wire antenna.



02-07-2018 09:29 PM

philso


Unread Re: pic: Finally some wire management

Quote:
Originally Posted by abigailthefox View Post
I don't want to rain on anyone's parade, but last year we wired our electronics board very similar to this and a judge dinged us for it. We only had 10 Talons (never thought I would be saying ONLY 10 Talons but here we are...), but the judge alerted us to the fact that wiring that many high-current wires close together can cause the creation of an electromagnetic field when powered on that can interfere with other wires nearby. In fact, we had issues previously with small "blips"—unexplained robot movement, but since these "blips" were always extremely brief, rare and seemingly idiopathic, we didn't worry about them too much. I was taking physics at the time, and his explanation (the details of which escape me now) did line up with what I had just learned. Needless to say, we will be spacing out our Talons this year.

I'm not saying it's necessary to change it and it does look great, But if you get a judge who wires things professionally, you may get a comment.
Congratulation! That is a very nicely laid out electronics panel and very nicely done wiring.

3360 has done it right. All of the courses I have attended and the textbooks I have for mitigating electromagnetic interference all say to do it the way they have done it.

Theoretically, the power wires will radiate a magnetic field. In reality, 3360's wiring practices should not cause problems.

The signal wires are running perpendicular to the power wires. That is the recommended way to route power and signal wires that must run near each other to minimize electromagnetic coupling. The signal wires appear to be run as twisted pair. Twisted pair greatly attenuates any interference by causing it to largely cancel itself. The CAN Bus devices have also been designed to very tolerant of induced noise.

Magnetic coupling is maximized when wires are run parallel to each other. The magnetic field strength is inversely proportional to the cube of the distance so even small spacings will attenuate the magnetic coupling dramatically. The wires are all far too short to be effective antennas at the switching frequency of the motor controller (and the higher power harmonics) so they would be very ineffective antennas in terms of radiating the magnetic flux and absorbing it. Thus, the impedance coupling the magnetic energy from one wire to the next is very high, say in the MegOhms or greater. The power circuits are all pretty low impedance, say a few Ohms or less. One can then think of these two impedances forming a divider circuit with a divide ration in the range of millions to one, or higher. The small amount of energy that does get coupled from one power wire into another is not going to circuit like a motor controller in any significant way. It would take a lot of radiated energy to have any significant effect, more than realistically can be generated in an FRC robot. This also means that it should be fine to place motor controllers right next to each other.

I suspect 1711's blips were more likely to be due to poor connections in some of the wiring than any form of electromagnetic interference.